Envio gratuito para compras: 100€

Garantia de devolução do dinheiro + informações

Pagamento seguro e financiamento + info

Are you from Canarias, Ceuta or Melilla?

¿Eres de Canarias, Ceuta o Melilla?

Zodiac Heat Line básico

Zodiac  |  SKU: W49NT70
1.055,21 €
Imposto incluído. Envio e descontos calculados na finalização da compra.
Págalo a plazos con
87,93€* al mes encuotas
No se ha podido mostrar la información solicitada
*Importe a financiar 1.055,21 € / incluye comisión de formalización 5,00 % (52,76€) / Comisión de formalización 5,00 % (52,76€) a pagar en la primera cuota / Plazo 12 meses / Importe total adeudado 1.107,97 € / TIN 0,00 % / TAE 9,91 % /  Ver másPrimera Cuota 87,93 €/ 11 cuotas de 87,93 € / Última cuota 87,98 € / Última cuota 87,93 / Total intereses 0,00 € / Coste total del crédito 52.76 € / Coste total del crédito 0,00 € / Precio de adquisición al contado 1.055,21 €. Precio total a plazos 1.107,97 €. Importe mínimo a financiar ≥ 90 € y cuota mínima ≥ 12 €. Sistema de amortización francés. Financiación ofrecida por Banco Cetelem S.A.U. La primera y la última mensualidad podrán variar en función de la fecha de puesta a disposición del préstamo. Válido hasta 30/11/2025Ver menos

Basic Zodiac Heat Line 70 heat exchanger. For heating outdoor or indoor pools up to 200 m3.

Zodiac Heat Line básico está esgotado e será enviado assim que estiver de novo em estoque.

Tempo de trânsito 1 - 3 dias

Pagamento seguro e prestações + info

Portes de envio gratuitos para encomendas: 100€ na península + info

Aconselhamento personalizado Contato

Garantia de devolução do dinheiro + informações

Descrição

Shell and tube heat exchangers

  • Compatible with all types of domestic heating systems (heat pump, boiler, geothermal and solar).
  • Simple installation.
  • Very resistant (titanium plates, Noryl / Polyamide body).
  • Other configurations available to adapt to all types of installations.

Operating principle

- The exchanger transfers the energy from the house's heating system to the pool water.
- Possible connection with all home heating systems (boiler, solar thermal panel, geothermal or aerothermal heat pump).
- If the primary heating circuit and filtration are far away, the heat exchanger must be placed near this primary circuit.
- Simple to use, it is only necessary to program the heater at 28ºC. The increase in temperature is reached within 2 to 5 days.
- To increase the temperature, place the filtration in continuous mode. Once the desired temperature is reached, reset the filtration to the automatic position.

Technical characteristics

Heat Line 20 Heat Line 40 Heat Line 70
References

W49NT20
W49KT20W
W49KT20

W49NT40
W49KT40W
W49KT40
W49NT70
W49KT70W
W49KT70
Maximum volume (m³) fifty 120 200
Power with primary at 90ºC (kW) twenty 40 70
Power with primary at 60ºC (kW) 8.5 17 30
Power with primary at 45ºC (kW) 4 8 14
maximum operating pressure 2b 2b 2b
max temperature admissible 90ºC 90ºC 90ºC
Weight (kg) 4 4 5
connections
syst. weather (caldera, solar) Ø26/34M Ø26/34M Ø26/34M
secondary pool PVC Ø 63 or 50 PVC Ø 63 or 50 PVC Ø 63 or 50
Flow (m³/h)
syst. weather (caldera, solar) 0.9 1.7 3
secondary pool 10 fifteen twenty
Load losses (mca)
syst. Climate (boiler, solar) 0.15 0.2 0.3
secondary pool 0.5 0.8 1